ANYSCAN® TRIO SPECT/CT

The only triple-detector SPECT/CT for high-end clinical and research applications with parallel hole and multi-pinhole collimation
AnyScan TRIO® SPECT/CT imaging system without any compromise to realize perfect SPECT resolution and excellent image quality. The unique triple head detector design enables detailed imaging by applying a reduced acquisition time. The system becomes a perfect Nuclear Medicine multimodality equipment with the supplement CT subsystem. With the addition of multipinhole collimation, the AnyScan TRIO® system breaks further boundaries in Molecular Imaging.

Optimized Time-Quality-Dose
Nuclear Medicine clinical practice requires high-throughput imaging systems that allow a significant reduction in acquisition times without degrading image quality. This is a legitimate request and our answer is the AnyScan TRIO® SPECT/CT multimodality imaging system.

Decrease Acquisition Time: The average acquisition time can be reduced to a quarter. A whole body bone SPECT/CT scan can be implemented in less than 20 minutes. The shorter acquisition time helps to improve patient comfort and decrease the chance of motion artefacts.
Maximize Image Quality: Improve diagnostic accuracy and confidence. Significantly higher system resolution and two times better contrast to noise ratio become available compared to the conventional two detector head SPECT systems.
Reduce Administered Activity: Minimize patient dose and reduce the exposure of the administrator. The smaller amount of applied tracers can dynamically reduce the average radiotracer cost.

Dedicated Brain imaging with SPECT Multi-PinHole technology in clinical research applications
Neurodegenerative diseases, like Alzheimer’s and Parkinson’s disease is of paramount importance in nuclear medicine thus Mediso introduces dedicated Brain SPECT multipinhole apertures and matching iterative reconstruction.

The main application is the brain imaging where a PET-like image resolution could finally be realized
High resolution brain imaging. One aperture for Alzheimer, Parkinson, Epilepsy
Shorter acquisition time with usual patient dosage allows 10 minute patient examinations

Dedicated Cardiac procedures with Multi-PinHole aperture
Improved heart acquisition methods with extreme high sensitivity and high resolution outcome
Even 2 minutes long cardio acquisition is possible in a special stationary collection
Lateral movement of the patient table helps to centralize the heart

High quality CT subsystem
The flexible AnyScan® SPECT system is supplemented by a 16-slice, low dose CT which results in a high resolution image. The detailed CT images help to localize anatomical aberrations and disorders accurately and give an exact input to SPECT acquisition planning. Attenuation correction from the CT image and our special Tera-Tomo™ 3D CT engine ensures sharp, detailed images. Metal correction function is available in CT reconstruction to reduce image artifacts caused by high attenuated orthopedic implants (e.g hip, knee, shoulder).

Scalable Detector performance for research & routine imaging
94(*3) / 123(*3) PMT, high resolution Xtreme Edition Detectors for multipinhole and parallel hole collimators for research and high energy theranostic imaging
Up to 3.0 mm resolution

Theranostic imaging with 19.1mm crystal high resolution detector
Theranostic imaging combined with therapy, is a rapidly growing application in cancer molecular imaging
To comply with the emerging sophisticated therapy need from clinical side, Mediso offers special detector perfect for theranostic imaging
Improved image quality for treatment purposes
Support of therapeutic isotopes such as I-131, Y-90, Lu-177.
Quantitative imaging